7917 S LOOMIS BLVD

ESC: NEEDED PRE-ESC: NOT ALLOWED BFEED REQ'D: 20A METER/SERVICE: SOCKET/OVERHEAD - RUSTY, DAMAGED PANEL: 100/100A TANDEM BREAKERS USED RECOMMENDED INTERCON: SUPPLY TAP SCOPE - REPLACE METER SOCKET WITH A NEW COMED APPROVED 100A METER SOCKET AND PAN. - REMOVE TANDEM BREAKER FROM THE MAIN SERVICE PANEL. REPLACE WITH A SIEMANS 15 AMP SINGLE PULL SINGLE THROW BREAKER. -REPLACE THE SPARE BREAKER IN SLOT #1 WITH A 15A BREAKER -LAND THE BRANCH CIRCUIT WIRES THAT WERE ON THE TANDEM ON THE NEWLY INSTALLED 15A BREAKERS. ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. AHJ CHICAGO GOVERNING ELECTRICAL CODE 2018 CHICAGO ELECTRICAL CODE

Permit

Permit type
PERMIT – EXPRESS PERMIT PROGRAM
Class
Unknown
Trade
Electrical
Nature of work
Other
Work
Electrical Work
Status
COMPLETE

Location

City
Chicago
State
IL

Dates

Applied
2020-10-06
Issued
2020-10-06
Time to issue
same day

Chicago details

Review type
EXPRESS PERMIT PROGRAM
Milestone
COMPLETE
Community area (code)
71