Chicago · permit B100894428
7816 S KILBOURN AVE
ESC: NEEDED PRE-ESC: NOT ALLOWED BFEED REQ'D: 40A METER/SERVICE: SOCKET/OVERHEAD PANEL: GE 100 (NO MAIN BREAKER) SERVICE CONDUCTORS TAPPED TO BUS RECOMMENDED INTERCON: SUPPLY TAP MAIN SERVICE PANEL IS LOCATED ABOVE GAS STOVE SCOPE RELOCATED MAIN SERVICE PANEL TO A CODE COMPLIANT LOCATION. RUN SERVICE ENTRY CONDUIT TO NEW PANEL. IF THE NEW PANEL LOCATION IS NOT WITHIN 5 FEET OF THE METER THEN INSTALL A 100A DISCONNECT WITH 5 FEET OF THE NEW PANELS LOCATION (EITHER INSIDE OR OUTSIDE) INSTALL A NEW JUNCTION BOX WHERE THE EXISTING PANEL WAS AND SPLICE AND REDIRECT BRANCH CIRCUITS TO THE MAIN SERVICE PANEL. ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. AHJ CHICAGO GOVERNING ELECTRICAL CODE 2018 CHICAGO ELECTRICAL CODE
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2020-10-06
- Issued
- 2020-10-06
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- VIVINT SOLAR DEVELOPER,LLC,
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 70