2852 N KOSTNER AVE

PANEL: 100/100A MAIN SERVICE PANEL DOES NOT HAVE A MAIN BREAKER; THE BREAKER LISTED AS THE SUB FEEDS THE SUB PANEL. _______________ SCOPE MAIN SERVICE PANEL DOES NOT HAVE A MAIN BREAKER; THE BREAKER LISTED AS THE SUB FEEDS THE SUB PANEL. REPLACE MAIN SERVICE PANEL WITH A 100/100A PANEL MINIMUM 30 BREAKER SLOTS INSTALL A 240 V BEAKER TO FEED THE SUB PANEL INSTALL NEW SERVICE ENTRANCE CABLE. IF MAIN SERVICE PANEL IS NOT WITHIN 5 FEET OF WHERE THE SEDRVICE ENTRANCE CABLE ENTERS THE HOME INSTALL A DISCONNECT ON THE INTERIOR WALL OF THERE THE CABLE ENTERS. AHJ: CHICAGO GOVERNING ELECTRICAL CODE: 2018 CHICAGO ELECTRICAL CODE CHECK AND FOLLOW AHJ AMENDMENTS PRIOR TO PERMIT ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. BOND STREET SIDE FIRST