Preview 1,066,918 permits — every permit Chicago, Austin and Seattle issued in the last ten years. The full load is in progress, so this is how far it has got. Sourced from city open-data portals. Data as of 2026-09-21.

Chicago · permit B200456002

7661 S SOUTH SHORE DR

INSTALL NEW GEOTHERMAL VERTICAL CLOSED LOOP WELLS IN REAR YARD OF EXISTING SINGLE-FAMILY HOME. EXCAVATION FOR GEOTHERMAL WELLS AND ASSOCIATED TRENCHING CANNOT BE LOCATED LESS THAN 1'-0" TO ADJACENT PROPERTY LINES. QUANTITY OF 50, 4" DIA. WELLS IN REAR YARD TO A DEPTH OF THIRTY FEET. TRENCHING SHALL NOT BE DEEPER THAN 36" BELOW FINISHED GRADE. SEE ASSOCIATED PERMITS 101074237 101004093 FOR MECHANICAL LAYOUT. NO NEW PARTITIONS OR EQUIPMENT CLOSETS.

Permit

Permit type
PERMIT – EXPRESS PERMIT PROGRAM
Class
Unknown
Trade
General/Building
Nature of work
Other
Work
Other Work
Status
ACTIVE

Location

City
Chicago
State
IL

Dates

Applied
2026-01-12
Issued
2026-05-14
Time to issue
122 days

Chicago details

Review type
EXPRESS PERMIT PROGRAM
Milestone
INSPECTIONS
Community area (code)
43

Data as of 2026-09-21.

Other permits issued in Chicago, May 2026