Chicago · permit B101032077
1908 W 22ND PL
INSTALL TWO MAIN SERVICE 100AMP DISCONNECT SWITCHES AS THE DISTANCE FROM THE POINT OF PENETRATION AFTER THE METERS INTO THE BUILDING IS GREATER THAN 5¿ WHICH IS REQUIRED BY CODE. - CONTINUE THE POWER SUPPLY RACEWAYS AFTER THE TWO DISCONNECT SWITCHES TO THE APARTMENT ELECTRICAL PANELS LOCATED IN THE BASEMENT COMMON AREA. - INSTALLATION OF POWER SUPPLY FROM THE METER BANK LOCATION TO THE PUBLIC/COMMON AREA PANEL WILL NOT REQUIRE A FORM OF DISCONNECT AS THE ELECTRICAL PANEL IS LOCATED WITHIN THE REQUIRED 5¿ OF PENETRATION. - INSTALL ¾¿ EMT CONDUIT FROM THE MAIN ELECTRICAL SERVICE TO THE MAIN WATER METER WITH #4AWG COPPER WIRE AND BOND FOR MAIN GROUNDING PURPOSES. - CLEAN UP ALL OF THE FLEXIBLE METALLIC WHIPS AT THE ELECTRICAL PANELS AS REQUIRED PER ELECTRICAL CODE. - INSTALL 1X OWNER PROVIDED LIGHT FIXTURE IN THE BASEMENT TO BE CONTROLLED BY A 3-WAY SWITCHING SYSTEM.
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE