Chicago · permit B101017408
2149 W BERWYN AVE
TESLA EV WALL CONNECTOR 1. FURNISH AND INSTALL (1) 60 AMP, 240 VOLT, 3 WIRE DEDICATED CIRCUIT. 2. PROPOSAL INCLUDES RUNNING (1) 3/4" RIGID EMT CONDUIT INSTALLED FROM THE EXISTING 200 AMP PANEL TO THE GARAGE. CONDUIT WILL BE SURFACE MOUNTED IN THE GARAGE. 3. CIRCUITRY WILL CONSIST OF (2) #6 AWG THHN COPPER CONDUCTORS AND (1) #10 AWG THHN GROUNDING CONDUCTOR. 4. INSTALL (1) CUSTOMER FURNISHED EV WALL CHARGER. WALL CONNECTOR WILL BE LOCATED ON THE BACK GARAGE WALL. 5. CHARGER WILL DELIVER UP TO 48 AMPS. 6. FURNISH AND INSTALL (1) DISCONNECT SWITCH AS REQUIRED BY CODE. DISCONNECT SWITCH WILL BE INSTALLED NEXT TO THE WALL CONNECTOR. 7. FURNISH AND INSTALL (1) 60 AMP 2 POLE BREAKER IN THE MAIN PANEL TO FEED THE WALL CONNECTOR. 8. PROVIDE (1) LOAD CALCULATION FOR THE HOUSE INCLUDING THE NEW CHARGER ¿ 9. PROPOSAL INCLUDES TRENCHING AND BACKFILLING. TRENCH WILL BE 4-6¿ WIDE BY 10-12¿ DEEP. PROPOSAL DOES NOT INCLUDE LANDSCAPE OR HARDSCAPE RESTORATION. THIS IS TO BE DONE BY OTHERS.