Chicago · permit B101007859
815 N PAULINA ST
EV LEVEL 2 WALL CONNECTOR PROPOSAL 1. FURNISH AND INSTALL (2) 60 AMP, 240 VOLT, 3 WIRE DEDICATED CIRCUIT. 2. FURNISH AND INSTALL (2) FUSED DISCONNECT SWITCH WITH A 60 AMP 2 POLE BREAKER NEXT TO THE METERS. DISCONNECT WILL BE TAPPED OFF OF THE YOUR UNITS METER. 3. PROPOSAL INCLUDES RUNNING (2) 3/4" RIGID EMT CONDUIT INSTALLED FROM EXISTING METER FITTINGS TO THE NEWLY INSTALLED DISCONNECT. THEN FROM THE DISCONNECT TO THE EV LEVEL 2 WALL CONNECTOR. CONDUIT WILL BE SURFACE MOUNTED IN THE MECHANICAL ROOM, UNDER THE DECK AND IN THE GARAGE. CONDUIT WILL ALSO BE TRENCHED IN FROM THE BUILDING TO THE GARAGE. 4. INSTALL (2) CUSTOMER FURNISHED TESLA WALL CHARGER. WALL CHARGER WILL BE LOCATED IN THE BACK CORNER ON THE NORTH WALL BY THE PARKING SPOT. 5. CIRCUITRY WILL CONSIST OF (2) #6AWG THHN COPPER CONDUCTORS AND (1) #10 AWG THHN GROUNDING CONDUCTOR. 6. CHARGER WILL DELIVER UP TO 48 AMPS. 7. PROPOSAL INCLUDES TRENCHING AND BACKFILLING FROM THE PORCH TO THE GARAGE. LANDSCAPE RESTORATION IS NOT INCL
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2023-03-07
- Issued
- 2023-03-07
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- REIN ELECTRIC, INC.
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE