Chicago · permit B100993869
4749 S WOODLAWN AVE
REPLACE CORRODED 125A 120/240V 3W METER HOUSING ON EXTERIOR REAR WALL. .DEMOLISH ILLEGAL CIRCUIT BREAKER PANEL IN BATHROOM. RELOCATE PANEL IN APPROVED BASEMENT LOCATION. INSTALL NEW MAIN GROUNDING CONDUIT AND CONDUCTOR, BONDING TO STREET-SIDE OF WATER METER, UTILIZING APPROVED COPPER AND BRASS CLAMPS, FITTINGS AND ID TAG. INSTALL SUPPLEMENTAL GROUND UTILIZING 5/8" DRIVEN COPPER GROUND ROD, EMT CONDUIT, #8 CONDUCTOR, BRASS GROUND CLAMPO AND ID TAG.
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2022-10-25
- Issued
- 2022-11-07
- Time to issue
- 13 days
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- PETER MC CARTHY ELECTRIC CO.
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 39