Chicago · permit B100989013
5812 N SACRAMENTO AVE
1. REMOVE ALL CLOTH COVERED WIRING 2. FURNISH AND INSTALL NEW WIRING 200 AMP SERVICE UPGRADE PROPOSAL $4,800.00 1. REMOVE EXISTING 100 AMP SERVICE AND REPLACE WITH A NEW 200 AMP SERVICE. 2. FURNISH AND INSTALL (1) 200 AMP OVER HEAD METER FITTING, 2" RIGID CONDUIT SERVICE RISER, AND #3/0 AWG THHN COPPER SERVICE ENTRANCE CONDUCTORS. 3. FURNISH AND INSTSALL (1) 200 AMP, MAIN BREAKER, 40 CIRCUIT PANEL. 4. FURNISH AND INSTALL ALL NEW BREAKERS AND LABEL THEM AS TO WHICH CIRCUITS THEY FEED. 5. FURNISH AND INSTALLATION NEW GROUNDING THAT COMPLIES WITH CURRENT CODES. THIS INCLUDES (2) GROUND RODS AND (1) WATER GROUND. 6. COORDINATE ALL PERMITS, INSPECTIONS, AND PAPERWORK WITH THE CITY OF CHICAGO. 7. PROPOSAL DOES NOT INCLUDE ANY PERMIT FEES OR FEES INCURRED BY COM ED. (NONE ANTICIPATED)
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2022-09-19
- Issued
- 2022-09-20
- Time to issue
- 1 day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- REIN ELECTRIC, INC.
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 2