Chicago · permit B100942633
8019 S KIRKLAND AVE
REPLACE METER SOCKET WITH 100A METER SOCKET/ENCLOSURE CECHA APPROVED - MILBANK PREFERED METER-MAIN IS NOW THE PRIMARY GROUND/BONDING POINT REPLACE AND RELOCATE SERVICE MAST AND WEATHERHEAD AND CONDUCTORS TO LOCATION WHERE SERVICE LATERAL WILL NOT MAKE CONTACT WITH METAL CHIMNEY. ENSURE CWG IS COMPLETED AND BONDED TO PV SYSTEM'S GROUNDING, NEED TO SEE EXISTING CWG IS LANDED ON STREET SIDE OF WATER METER/SHUT OFFS. REPLACE MAIN SERVICE PANEL WITH A 125/100A PANEL MINIMUM 30 BREAKER SLOTS REDO SOLAR CONDUIT FROM METER TO INVERTER TO ENSURE CONDUIT RACEWAY AND REMOVE ALL FMC FROM SOLAR RACEWAY. RUN NEW SERVICE ENTRANCE CONDUIT, USE MOGUL LB'S WHERE NEEDED (INSIDE AND OUTSIDE). PULL NEW SERVICE CONDUCTORS DIRECTLY TO THE NEW PANEL.
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2021-10-01
- Issued
- 2021-10-01
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- VIVINT SOLAR DEVELOPER,LLC,
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 70