3255 S SPRINGFIELD AVE

REPLACE METER SOCKET WITH U8949-RL-TG-KK-CECHA (100-200 AMP) - MILBANK METER IS NOW THE PRIMARY GROUND/BONDING POINT PULL NEW SERVICE CONDUCTORS DIRECTLY TO THE NEW PANEL. GROUND/BOND COLD WATER - STREET SIDE FIRST CLEAN UP MAIN SERVICE PANEL, SEVERAL MISMATCHED BREAKERS, (3 X 15 AMP, 3 X 20 AMP, 2 X 30 AMP BREAKERS NEED TO BE REPLACED WITH EQUILIVANT GE BREAKERS) AND OPEN K.O."

Permit

Permit type
PERMIT – EXPRESS PERMIT PROGRAM
Class
Unknown
Trade
Electrical
Nature of work
Other
Work
Electrical Work
Status
COMPLETE