Chicago · permit B100922435
5052 S LAPORTE AVE
SCOPE REPLACE AND MOVE TO A CODE COMPLIANT LOCATION. METER SOCKET WITH U8949-RL-TG-KK-CECHA (100-200 AMP) - MILBANK FOR INTERCONNECTING USING THE LUGS IN THE METER. LUG KIT K4977-EXT - EXTERNAL HEX - REPLACE RISER WITH SERVICE CABLE AND INSTALL A NEW WEATHERHEAD. - RUN NEW SERVICE ENTRANCE CONDUIT, USE MOGUL LB'S WHERE NEEDED (INSIDE AND OUTSIDE). PULL NEW SERVICE CONDUCTORS DIRECTLY TO THE NEW PANEL. - REPLACE MAIN SERVICE PANEL WITH A 100/100A PANEL MINIMUM 30 BREAKER SLOTS - - MAKE SURE THE PANEL SCHEDULE IS FILLED OUT AHJ: CHICAGO GOVERNING ELECTRICAL CODE: 2018 CHICAGO ELECTRICAL CODE CWG NEEDED ? YES
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE