6643 S KEDVALE AVE
SCOPE INSTALL A J-BOX IN THE EXISTING PANELS LOCATION AND MOVE THE ESITING PANEL TO A CODE COMPLIANT LOCATION - IF THE NEW MSP LOCATION IS FURTHER THAN 5 FEET FROM WHERE THE SERVICE ENTERS THE HOME THEN A SERVICE DISCONNECT WILL NEED TO BE INSTALLED INSIDE THE HOME WITHIN 5 FEET OF SERVICE ENTRY - RUN NEW SERVICE ENTRANCE CONDUIT, USE MOGUL LB'S WHERE NEEDED (INSIDE AND OUTSIDE). PULL NEW SERVICE CONDUCTORS DIRECTLY TO THE NEW PANEL. - PULL NEW SERVICE ENTRY CONDUCTORS - RUN CONDUITS BETWEEN THE NEW JBOX AND THE NEW MSP LOCATION. RUN ENOUGH CONDUITS SO THAT NO MORE THAN 8 CURRENT CARRYING CONDUCTORS ARE IN THE SAME CONDUIT. - SPLICE AND GROUP BRANCH CIRCUITS AND RUN THEM INTO THE MSP AND TERMINATE. MAKE SURE THE PANEL SCHEDULE IS FILLED OUT AHJ: CHICAGO GOVERNING ELECTRICAL CODE: 2018 CHICAGO ELECTRICAL CODE CHECK AND FOLLOW AHJ AMENDMENTS PRIOR TO PERMIT ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. BOND STREET SIDE FIRST