SCOPE RUN NEW SERVICE ENTRANCE CONDUIT AND MAST , USE MOGUL LB'S WHERE NEEDED (INSIDE AND OUTSIDE). PULL NEW SERVICE CONDUCTORS DIRECTLY TO THE NEW PANEL. 1 1/4" RMC - REMOVE THE EXISTING MSP AND INSTALL A JUNCTION BOX. - INSTALL A NEW 100/100A MSP A FEW FEET TO THE RIGHT OF WHERE THE OLD MSP WAS. - RUN CONDUITS BETWEEN THE J-BOX AND NEW MSP. SPLICE THE BRANCH CIRCUITS AND RUN INTO THE NEW MSP. ONLY 9 CURRENT CARRYING CONDUCTORS ARE ALLOWED PER CONDUIT. - PULL NEW RISER AND SERVICE ENTRANCE CONDUCTORS. #3 COPPER. - TIE IN THE PV WITH A SUPPLY TAP IN THE MSP. - FINISH THE GROUNDING TO THE METER. MAKE SURE THE PANEL SCHEDULE IS FILLED OUT AHJ: CHICAGO GOVERNING ELECTRICAL CODE: 2018 CHICAGO ELECTRICAL CODE CHECK AND FOLLOW AHJ AMENDMENTS PRIOR TO PERMIT ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. BOND STREET SIDE FIRST
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2021-04-16
- Issued
- 2021-04-16
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- VIVINT SOLAR DEVELOPER,LLC,
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 66