Chicago · permit B100852934
720 W BUENA AVE
220 VOLT AC LINE/SUB-PANEL $3,350.00 1. FURNISH AND INSTALL (1) 60 AMP, 8 CIRCUIT SUB PANEL. SUB PANEL WILL BE LOCATED THROUGH THE DOORS, ON THE INTERIOR WALL SHARING WITH THE 2ND DOOR. 2. FURNISH AND INSTALL (1)1" CONDUIT FROM THE EXISTING PANEL TO THE NEW SUB PANEL. 3. CIRCUITRY WILL CONSIST OF (3) #3 AWG THHN CU CONDUCTORS AND (1) #8 AWG THHN GROUNDING CONDUCTOR. 4. FURNISH AND INSTALL (1) 60 AMP, 2 POLE BREAKER IN THE EXISTING PANEL. 5. RE-WORK (2) EXISTING BRANCH CIRCUITS INTO THE NEW SUB PANEL. CIRCUITS WILL GO THROUGH THE 1" CONDUIT. 6. FURNISH AND INSTALL (1) 3/4" CONDUIT FROM THE SUB PANEL TO THE 3RD FLOOR UNIT. 7. CIRCUITRY WILL CONSIST OF (2) #8 AWG THHN CONDUCTORS, (1) #12 AWG THHN GROUNDING CONDUCTOR. 8. FURNISH AND INSTALL (1) WEATHER PROOF BOX ON THE EXTERIOR OF THE 3RD FLOOR MASTER BEDROOM. CIRCUIT WILL DEAD END IN THIS BOX.
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2019-12-04
- Issued
- 2019-12-04
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- REIN ELECTRIC, INC.
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 3