Chicago · permit B100851937
3113 N KENMORE AVE
NEMA 14-30R (OWNER'S PANEL) $1,835.00 1. FURNISH AND INSTALL (1) 30 AMP, 240 VOLT, 4 WIRE DEDICATED CIRCUIT. 2. FURNISH AND INSTALL (1) 30 AMP FUSED DISCONNECT IN THE BASEMENT NEXT TO THE EXISTING ELECTRICAL SERVICE. FUSED DISCONNECT WILL FEED THE 14-30R AND BE TAPPED OFF OF THE MAIN SERVICE CONDUCTORS FEEDING YOUR UNIT'S PANEL. 3. PROPOSAL INCLUDES RUNNING (1) 1/2" RIGID EMT CONDUIT INSTALLED FROM THE NEWLY INSTALLED DISCONNECT TO THE GARAGE PARKING SPOT. 4. CIRCUITRY WILL CONSIST OF (3) #10 AWG THHN COPPER CONDUCTORS AND (1) #10 AWG THHN GROUNDING CONDUCTOR. 5. FURNISH AND INSTALL (1) NEMA 14-30R. RECEPTACLE WILL BE LOCATED ON THE BACK GARAGE WALL. 6. RECEPTACLE WILL DELIVER 22 AMPS AND PROVIDE 20 MILES PER HOUR OF CHARGE. (MODEL 3) 7. PROVIDE (1) LOAD CALCULATION FOR THE HOUSE PANEL INCLUDING THE NEW TESLA CHARGER. 8. PROPOSAL INCLUDES TRENCHING AND BACKFILLING. LANDSCAPE RESTORATION IS NOT INCLUDED
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2019-11-21
- Issued
- 2019-11-21
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- REIN ELECTRIC, INC.
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 6