Chicago · permit B100824725
680 N PEORIA ST
TESLA EV CHARGER NEMA 14-50R 1. FURNISH AND INSTALL (1) 50 AMP, 240 VOLT, 4 WIRE DEDICATED CIRCUIT. 2. PROPOSAL INCLUDES RUNNING (1) 3/4" RIGID EMT CONDUIT INSTALLED FROM 200 AMP PANEL TO THE GARAGE. CONDUIT WILL BE SURFACE MOUNTED IN THE BASEMENT AND THE GARAGE. 3. CIRCUITRY WILL CONSIST OF (3) #6AWG THHN COPPER CONDUCTORS AND (1) #10 AWG THHN GROUNDING CONDUCTOR. 4. FURNISH AND INSTALL (1) NEMA 14-50R. RECEPTACLE WILL BE LOCATED THE EAST GARAGE WALL, CLOSER TO THE BAY DOOR. 5. RECEPTACLE WILL DELIVER 32 AMPS AND PROVIDE 30 MILES PER HOUR OF CHARGE. (MODEL 3) 6. FURNISH AND INSTALL (1) 50 AMP, 2 POLE BREAKER 7. PROVIDE (1) LOAD CALCULATION FOR THE HOUSE INCLUDING THE NEW TESLA CHARGER
Permit
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Class
- Unknown
- Trade
- Electrical
- Nature of work
- Other
- Work
- Electrical Work
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2019-06-11
- Issued
- 2019-06-11
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- REIN ELECTRIC, INC.
Chicago details
- Review type
- EXPRESS PERMIT PROGRAM
- Milestone
- COMPLETE
- Community area (code)
- 24