Chicago · permit 100935050
4930 S LANGLEY AVE
RELOCATE BETA ANTENNAS TO LOWER PENTHOUSE AT 123'-0" RADREMOVE 1X EXISTING SBNHH-1D65B ANTENNA FROM P0S2.RELOCATE 1X EXISTING RRUS-32 830 FROM POS2 TO POS1 AND CONNECT IT TO EXISTING ANTENNA ON POS1.INSTALL 1X NEW AIR6449 B77D CBAND ANTENNA ON POS3.INSTALL 1X NEW CBC78T-DS-43 DIPLEXER ON POS4 AND CONNECT IT TO EXISTING ANTENNA ON POS4.RECONNECT 2 PORTS OF EXISTING 4478 B14 TO NEW DIPLEXER ON POS4. RECONNECT EXISTING UMTS 850 TO NEW DIPLEXER ON POS4.REMOVE EXISTING UMTS TMA'S. REMOVE »« GSM EQUIPMENT IF EXISTINGINSTALL 1X DC9 PER SECTOR WITH 3X 6AWG6 DC TRUNKS. REUSE EXISTING 3X 18 PAIR FIBER TRUNKS AND 6X 8AWG6 DC TRUNKS. REMOVE 3X EXISTING DC6'S . EXISTING ARGUS-48V (AS PER JSA)INSTALL NEW OUTDOOR RAYCAP MODEL# DC12-48-60-0-25E (AS PER JS
Permit
- Permit type
- PERMIT - RENOVATION/ALTERATION
- Class
- Unknown
- Trade
- General/Building
- Nature of work
- Alteration
- Status
- COMPLETE
Location
- City
- Chicago
- State
- IL
Dates
- Applied
- 2021-08-12
- Issued
- 2021-08-12
- Time to issue
- same day
Value and contractor
- Declared value
- Log in with your free account
- Total fee
- Log in with your free account
- Contractor
- DEERFIELD CONSTRUCTION GROUP, INC
Chicago details
- Review type
- STANDARD PLAN REVIEW
- Milestone
- COMPLETE
- Community area (code)
- 38