Preview 555,290 permits — every permit Chicago, Austin and Seattle issued in the last ten years. The full load is in progress, so this is how far it has got. Sourced from city open-data portals. Data as of 2026-09-21.

Chicago · permit 100835085

2000 N LINCOLN PARK W

EXISTING SPRINT EQUIPMENT TO BE REMOVED: 3 CW PANEL ANTENNAS WITH ASSOCIATED CABLING; 3 CW RRHS; 1 CLEARWIRE BACKHAUL EQUIPMENTTO BE INSTALLED: 3 SAMSUNG B41 64T64R MIMO ANTENNAS; 3 MIMO MOUNTING BRACKETS; 3 DUALBAND ANTENNA; 3 RRH-C4; 3 RRH-P4; 3 1.11 HFC CABLE; 1 40A BREAKER IN EXISTING PPC; 1 ELTEK CABINET; 1 PPC ON WALLREINFORCE THE EXISTING FRAME AS FOLLOWS FOR EACH SECTOR. SECTOR ALPHA: ADD ADDITIONAL BALLAST WEIGHT ON ALL TRAYS SUCH THAT EACH TRAY SHOULD BE LOADED WITH MINIMUM 189 LBS; MOUNT TO BE RE-ORIENTED TO AVOID ANTENNA SKEWSECTOR BETA: INSTALL BRACING MEMBER OF ANGLE CONNECTING BOTH TOP FACE HORIZONTAL AND BOTTOM FACE HORIZONTAL AT A DISTANCE OF 27.5" FROM THE PROJECTED END OF THE FACE HORIZONTAL TOWARDS MOUNT CENTRE; INSTALL A BRACING MEMBER OF ANGLE CONNECTING BOTH TOP FACE HORIZONTAL AND BOTTOM FACE HORIZONTAL AT A DISTANCE OF 32" FROM THE OTHER END OF FACE HORIZONTAL TOWARDS MOUNT CENTRE; INSTALL A DIAGONAL OF ANGLE CONNECTING TOP BRACING MEMBER WITH BOTTOM BRA

Permit

Permit type
PERMIT - RENOVATION/ALTERATION
Class
Unknown
Trade
Electrical
Nature of work
Alteration
Status
COMPLETE

Location

City
Chicago
State
IL

Dates

Applied
2019-08-14
Issued
2019-08-14
Time to issue
same day

Chicago details

Review type
STANDARD PLAN REVIEW
Milestone
COMPLETE
Community area (code)
7

Data as of 2026-09-20.