Preview 316,582 permits — every permit Chicago, Austin and Seattle issued in the last ten years. The full load is in progress, so this is how far it has got. Sourced from city open-data portals. Data as of 2026-09-20.

Chicago · permit 100757850

1627 N RUTHERFORD AVE

INSTALLATION OF PUSH PIERS ON THE NORTHWEST CORNER IN ORDER TO STABILIZE THE FOUNDATION FROM FURTHER SETTLEMENT. WE HAVE DETERMINED THAT IN ORDER TO STABILIZE THE FOUNDATION, WE WOULD NEED TO INSTALL SIX (6) PUSH PIERS. TWO (2) OF THESE WOULD BE ON THE WEST WALL AND THE REMAINING FOUR (4) WILL BE ON THE NORTH WALL.THIS WILL BE ACCOMPLISHED BY EXPOSING THE FOOTING OF THE FOUNDATION AND INSTALLING LOW-PROFILE BRACKETS. THE PIERS WILL BE HYDRAULICALLY PRESSED INTO THE GROUND THROUGH THESE BRACKETS TO A MINIMUM PRESSURE OF 3,430 PSI. ONCE EACH INDIVIDUAL PIER HAS REACHED PRESSURE, WE WILL TRANSFER THE WEIGHT OF THE FOUNDATION ONTO THE PIERS, STABILIZING AGAINST FURTHER MOVEMENT.

Permit

Permit type
PERMIT - RENOVATION/ALTERATION
Class
Unknown
Trade
General/Building
Nature of work
Alteration
Status
COMPLETE

Location

City
Chicago
State
IL

Dates

Applied
2018-06-01
Issued
2018-10-25
Time to issue
146 days

Value and contractor

Declared value
Log in with your free account
Total fee
Log in with your free account
Contractor
THE REAL SEAL LLC

Chicago details

Review type
STANDARD PLAN REVIEW
Milestone
COMPLETE
Community area (code)
25